Quick Entrance
CN | Japanese


Respiratory Syncytial Virus / Adenovirus / Parainfluenza virus Nucleic Acid Detection Kit (Fluorescence PCR) is used for the qualitative detection of the Respiratory Syncytial Virus (RSV), Adenovirus (ADV) and Parainfluenza virus (PIV) nucleic acid in specimens of oropharyngeal swabs from suspected cases. The kit is used for the auxiliary diagnosis and epidemiological surveillance of RSV, ADV and PIV infection, cannot be used as the basis for the diagnosis or exclusion of cases alone.


Product Details FAQ Specification Instructions

This product selects highly conserved regions of Respiratory Syncytial Virus, Adenovirus and Parainfluenza virus to designs specific primers and fluorescent probes. The 5' end of the probe is labeled with the fluorescence reporter and the 3' end is labeled with the fluorescence quencher. During PCR amplification, when the probe maintains the complete sequence, the fluorescence of the fluorescence reporter is absorbed by the fluorescence quencher without producing fluorescence.

When the probe is bound to the template, the probe will be cut off by the 5'→3' exonuclease activity of DNA polymerase, and the fluorescence reporter will be separated from the fluorescence quencher, and the fluorescence cannot be absorbed by the quencher, resulting in a fluorescence signal. The fluorescence PCR instrument will automatically draw a fluorescence curve according to the detected fluorescence signal and determine the detection result. In order to control the whole process of sampling, extraction and PCR amplification, human gene was act as a non-competitive internal control during the detection process.




The Kit (Fluorescence PCR) is used for the qualitative detection of the Respiratory Syncytial Virus (RSV), Adenovirus (ADV) and Parainfluenza virus (PIV) nucleic acid in specimens of oropharyngeal swabs from suspected cases.





1. The unopened kit should be stored at -20℃±5℃ away from light.

2. The kit can be stored for up to 12 months if all components are kept in the manner above. Do not use after the stated expiry date.

3. The kit can be transported for 7 days at temperatures not exceeding 8°C

without affecting its validity period.

4. Don’t open unless you are ready to use the kit. The kit can be stored for 7 days at 2~8℃ after opening.

5. Avoid repeated freeze-thaw (no more than 5 times).


Cat# Product Name Packing size
BSJ45M1

Respiratory Syncytial Virus / Adenovirus / Parainfluenza

 Virus Nucleic Acid Detection Kit (Fluorescence PCR)

48T
BSJ45L1

Respiratory Syncytial Virus / Adenovirus / Parainfluenza

 Virus Nucleic Acid Detection Kit (Fluorescence PCR)

96T