Quick Entrance
CN | Japanese

BioEasy 5×qPCR Master Mix (Lyophilizable) is specifically designed and developed to facilitate lyophilization for fluorescent quantitative PCR products. It contains the novel fast hot-start enzyme BioQuick Hot Start Taq, which effectively suppresses non-specific amplification, thereby enhancing the specificity of the amplification reaction. BioEasy 5×qPCR Master Mix (Lyophilizable) includes an optimized buffer system, dNTPs, Mg2+, and factors that significantly improve the efficiency of the amplification reaction, making it suitable for a wide range of specific fluorescent PCR tests. This product is compatible with the BioEasy fluorescent quantitative PCR instrument platform, allowing for a shortened amplification time of 25 minutes, effectively saving testing time. Users can perform lyophilization on this product as needed, and the lyophilized product maintains excellent lyophilization characteristics, reconstitution ability, and stability.


Product Details FAQ Specification Instructions

The reagent is designed as a ready-to-use, lyophilizable solution for detection and quantitation of target RNA sequences using hydrolysis probes. This pre-mixed formulation can be flexibly applied to single-target or multiplex RT-qPCR by adding primers, probes and templates. This product contain optimized buffer, Mg2+, dNTPs, hot-start quick Taq DNA polymerase, reverse transcriptase, lyophilized protectants and excipients. Hot-start Taq DNA polymerase and stabilizers result in high amplification efficiency and low non-specific amplification. This product does not contain ROX reference dyes. The reagent is used for lyophilized products which show good lyophilized appearance, reconstitution and stability.


1. Convenient Application: Pre-mixed Master Mix, requiring only the optimization of primers and probes.

2. Good Lyophilization Homogeneity: Can be lyophilized with stability ensured through Sork technology before lyophilization.

3. Short Lyophilization Cycle: Utilizes a three-stage lyophilization process with a cycle of approximately 27 hours.

4. Short Detection Time: RNA sample testing can be completed in under 30 minutes.



Experimental Comparison and Validation of BioEasy 2 × RT qPCR Master Mix (Lyophilizable) and supplier A brand premix were used to test the detection performance of novel coronavirus genes (ORF1ab and N genes). The test samples were the products extracted from novel coronavirus culture, and were diluted with 10 times concentration gradient respectively. The test results are shown in Figure 1, Figure 2 and Table 1.




Results: The results demonstrate that BioEasy 2×RT-qPCR Master Mix (Lyophilizable) as a lyophilized reagent exhibits significantly better detection performance compared to Brand A.


1. The kit should be transported in foam box sealed with ice bags or dry ice at 2-8℃ or lower.

2. Kit storage: Store in a -25~-15°C refrigerator away from light, and the repeated freezing and thawing should not exceed 7 times.

3. Validity period: 12 months, please use within the validity period.