Quick Entrance
CN | Japanese

Respiratory tract infection is one of the most common infectious diseases worldwide, most of which are bacterial lower respiratory tract infections. Bacterial infection or secondary infection often causes exacerbation of respiratory disease symptoms. There are many pathogens that can cause respiratory tract infection, among which Streptococcus pneumoniae (SP) and Haemophilus influenzae (HI) are important pathogenic bacteria. Two Bacteria Also Major Bacterial Causes of Community Acquired Pneumonia. This kit adopts the fluorescent PCR method, and is equipped with QuantGene 9600 and LineGene 9600 Plus real-time fluorescent quantitative PCR instruments produced by Hangzhou Bioer Technology Co., Ltd., as well as ABI7500. It has the characteristics of fast detection speed, good specificity and high sensitivity

This kit selects highly conserved regions of Streptococcus pneumoniae and Haemophilus influenzae, and designs specific primer probes. The primers and probes can specifically bind to the target sequence, and under the action of Taq enzyme, the fragment can be specifically amplified, and the fluorescent Probes are hydrolyzed during amplification, resulting in fluorescence. The detection system contains dUTP-UDG enzyme anti-pollution measures to fully degrade possible product contamination and avoid false positive results; in addition, an internal standard is set, which is a highly conserved region on the human genome, and the internal standard monitors sample collection, transportation, nucleic acid extraction and PCR amplification. Increase the whole process, avoid false negative results, and ensure the effectiveness of the whole process.

Product features

Product parameters
Experimental data

1. Clinical specimen experiment: Bioer extraction kit BSC71S1E is used to extract and detect clinical specimens of Streptococcus pneumoniae and Haemophilus influenzae. At the same time, the detection kit of the same kind that have obtained NMPA certificate are used as a comparison to verify the compliance rate.

Result: The results show that: compared with the competing product of Streptococcus pneumoniae and Haemophilus influenzae detection kits, the clinical samples verified by Bioer Streptococcus pneumoniae and Haemophilus influenzae detection kit has a higher detection coincidence rate and higher amplification efficiency.

2. Accuracy: after the positive reference products P1-P10 and negative reference products N1-N10 of Hangzhou Bioer Technology Co., Ltd. are reconstituted as required, they are extracted with Bioer extraction kit BSC71S1E and tested.

Result: The results show that the nucleic acid of Streptococcus pneumoniae and Haemophilus influenzae can be accurately detected. The test results of enterprise reference products: the positive coincidence rate is 100%, and the negative coincidence rate is 100%

3. Linear relationship: Take 10-fold gradient samples of Streptococcus pneumoniae, and use Bioer extraction kit BSC71S1E to extract and detect respectively.

Result: The results showed that the correlation coefficients of Streptococcus pneumoniae and Haemophilus influenzae were above 0.995, and the linear relationship is great.


Contact us
  • *Name:
    *Mailbox:
  • Phone:
    *Company:
  • *Message:
*Name:
*Mailbox:
Phone:
*Company:
*Message: