In order to lead the market development trend, meet the demand of PCR detection of automation, Bioer technology developed Automated Nucleic Acid Purification and Real Time PCR System , realized the: "sample pre-treatment + nucleic acid extraction + fluorescence quantitative PCR" of the whole experiment process, can help you meet the growing needs of your lab with highly efficient workflows, from sample processing to result interpretation, fully enclosed pollution prevention design, the maximum guarantee the stability of high efficiency and results of the experiment process.At the same time, the low throughput design with continuous sample addition can meet the needs of different types of customers for flexible testing.
Implementation: The whole automated process of sample pre-treatment + nucleic acid extraction + fluorescence quantitative PCR
Drive laboratory efficiency in a number of ways,the first round results will be completed within 1 hour and the next round results will be issued every 30 minutes
Fully enclosed design, unique sample processing unit, minimizes contamination
Touch - controlled interface, full automatic result analysis, easy to operate
Product Name | Automated Nucleic Acid Purification and Real Time PCR System | |||||
---|---|---|---|---|---|---|
Model | FQD-A1600 | |||||
Sample throughput | 16 (applies to sample storage tubes, vacuum blood collection tubes, 1.5 ml and 2 ml centrifuge tubes, measuring cups, etc.) | |||||
Pipetting performance |
Under 5 µl: Accuracy ≤±5%,repeatability ≤5% 5 µl to 10 µl: Accuracy ≤±5%,repeatability ≤3% 10 μL to 50 μL: Accuracy ≤±3%, repeatability ≤1.5% Over 50 μL: Accuracy ≤±2%, repeatability ≤1% |
|||||
Nucleic acid purification processing volume | 20-1000 μL | |||||
Magnetic bead recovery efficiency | ≥98% | |||||
Purification pore variance | CV < 3% | |||||
PCR reaction system | 5-30ul | |||||
Detection channel/ Applicable dyes | F1: FAM, SYBR Green I; F2: VIC, HEX, TET,JOE; F3: ROX, TEXAS-RED; F4: Cy5 Quasar -670; F5: Cy5.5 Quasar -705; F6: Cy3 Tamra | |||||
Module working temperature range | 4 - 99.9 ℃ (minimum setting scale: 0.1 ℃) | |||||
Average heating rate | From 50℃ to 90℃, should not be less than 8℃/s | |||||
Average cooling rate | From 90℃ to 50℃, should not be less than 5℃/s | |||||
Module temperature control accuracy | Should not be greater than 0.1℃ | |||||
Temperature uniformity | Temperature difference is within 0.4℃ | |||||
Information Technology | Multiple sample barcodes are scanned one by one during sample rack loading. | |||||
Fluorescence intensity detection repeatability | CV≤1% | |||||
Input power | 220V - 50Hz 2800VA | |||||
Overall dimensions | 1850mm×730mm×1530mm (length, width, height) |