This kit covers the types of HPV prevented by the quadrivalent vaccine (HPV 6/11/16/18). Specific primer probes were designed after selecting the conserved regions of HPV genome, and different fluorescence groups were labeled on the probes to produce different fluorescence in the reaction system. Four virus subtypes, HPV-6, 11, 16 and 18, can be classified and detected in only one detection, which can provide effective diagnostic basis for doctors and have guiding significance for diagnosis and treatment.

Product features
  • There is no cross reaction between HPV-26313335394551525356585966687382
    404243445461676970717281 and 83 in this kit.

  • There was no cross-reaction with the human genome, ureaplasma urealyticum, chlamydia trachychondria, herpes simplex virus TYPE II, human cytomegalovirus, treponema pallidum, Mycoplasma hominis, Neisseria gonorrhoeae, Candida albicans, trichomonas vaginalis, Staphylococcus aureus, hepatitis B virus and hepatitis C virus.
  • At the same time, the presence of hemoglobin, white blood cells, cervical mucus, vaginal contraceptives, feminine hygiene products, vaginal antifungal drugs and vaginal lubricants did not affect the testing of the samples.
  • Certificate: CE-IVD.

Product parameters
Cat.No Product Name Package
BSJ24M1 HPV (6/11/16/18) Genotyping Real-Time PCR Kit 48T
Experimental data

Case 1. National reference HPV-6, 11, 16, and 18 were diluted 0 and 100 times, respectively, and repeated 20 times to calculate their precision.



Result: The results showed that the CV of the above four types was ≤5%, indicating that the kit had excellent performance and high precision.

Case 2. National references for HPV-6, 11, 16, and 18 were mixed, diluted at a 10-fold gradient, extracted with Bioer MagaBio plus Virus DNA/RNA Purification Kit II and tested with this kit.


Result: The results showed that HPV-6, 11, 16 and 18 types could be detected simultaneously in the same reaction tube, and the amplification correlation coefficient of each detected target gene was high, the linear relationship was good, and there was no obvious interference between each other.

Case 3. Bioer MagaBio plus Virus DNA/RNA Purification Kit II was used to extract HPV clinical samples for testing, and its detection performance was verified by comparing with competing reagent products.



Result: The results showed that compared with the competing reagent products, the clinical samples tested by this kit had a higher coincidence rateKappa0.8).